Sign In | Join Free | My entremaqueros.com
China Guangzhou GENY Electric Co., Ltd logo
Guangzhou GENY Electric Co., Ltd
Professional in Energy Meter Testing
Verified Supplier

2 Years

Home > Stationary Meter Test Bench >

Three Phase Stationary Meter Test Bench

Guangzhou GENY Electric Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Three Phase Stationary Meter Test Bench

Brand Name : GENY

Model Number : YC-1893D

Place of Origin : CHINA

Certification : ISO, CE

MOQ : 1

Payment Terms : L/C, D/P, T/T, D/A

Supply Ability : 10 pcs/ 3 months

Delivery Time : 8 ~10weeks

Packaging Details : Plywood cases

Model no. : YC1893D-24-0.02-F

Accuracy class : 0.02%

Operation Temperature : -10ºC--+40ºC

Humidity : -35%--85%

Power of the current output : 3×2000VA

Contact Now

Professional Three-Phase Stationary Meter Test Bench for Electric Energy Meter Testing

Stationary Three Phase Meter Test Bench

The YC1893D meter test system is a full-automatic test system for testing and calibration of both single-phase and three-phase electric energy meters, which composes of:

  • Three-phase Power source
  • Three-phase Reference standard meter
  • Meter suspension test racks for testing of both 1-phase/3-phase meters
  • Smart meter function test system (fixed voltages, optical probe, relay control test and ripple control box as option)
  • Other necessary parts
  • PC and software controlling the whole system


The YC1893D meter test system is fully compliant with the IEC 60736 standard and is suitable for testing meters according to the following standards:

  • IEC 62052-11 and IEC 62053-11, -21, -22, -23, -24
  • IEC 62056
  • EN 50470-1, EN 50470-2, EN-50470-3
  • IEC 61010


Features

  • The meter test system can measure mechanical meters, electronic mechanical meters and electronic meter by the way of automatic, semi-automatic or manual operation.
  • Aluminium alloy material, light and strong and corrosion resistant.
  • Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.
  • The swing together of the scanning heads simplifies the control.
  • Fully automatic completion of the following tests:
    • Accuracy test in all four quadrants (active, reactive and apparent energy)
    • Repeatability of error test
    • Creep test (No-load test)
    • Starting current test
    • Dial test (Register test)
    • Meter constant test
    • Influence quantity test (voltage, voltage unbalance, frequency, harmonic distortion, reverse phase sequence.)
    • Calibration of reference standard meter having lower accuracy than the employed reference standard
    • Pre-warming
    • Dips and Interruptions
    • Testing single-phase meters under tampered conditions
    • Sub Harmonics as per IEC standards
    • Odd Harmonics as per IEC standards
  • Measuring different constants of meters synchronously.
  • With the protection function of overload, short voltage circuit and open current circuit.

Technical specification

The test bench is multiple positions up to 24 meters, 0.02% of accuracy class Three-phase Meter Test System with ICTs, with multiple serial port communication system for parallel communication for testing of smart meters.

  • Power Supply

Voltage 3x230 / 400 V ±10%, 50 / 60 Hz ±2 Hz
Frequency 50 Hz ±15%
Power capacity > 6 kVA
Power efficient(at full load) ≥85%
Ambient temperature -10 °C -- +40 °C
Relative humidity 35% - 85%

  • Power Source

Voltage
Test voltage output (Phase-Neutral) 3x(24 – 300 V)
Power of the voltage output 3×1000VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load < 0.01%
Distortion factor < 0.3% for linear resistance load
Harmonics 2nd – 41st free programmable
Current
Test current output 1 mA – 120 A
Power of the current output 3×2000VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load < 0.01%
Distortion factor < 0.3% for linear resistance load
Harmonics 2nd – 41st free programmable
Phase angle
Range 0 -- 360°
Resolution 0.01°
Setting accuracy 0.1°
Frequency
Range 45 Hz – 65 Hz
Resolution 0.01 Hz

Structural diagram of stationary meter test bench

Three Phase Stationary Meter Test Bench
Three Phase Stationary Meter Test Bench
Three Phase Stationary Meter Test Bench
Three Phase Stationary Meter Test Bench
*If you want to know more please check our official website:http://www.genymetertestequipment.com/

Product Tags:

Stationary Meter Test Bench

      

Three Phase Meter Test Bench

      

Calibrate Meter Test Bench

      
 Three Phase Stationary Meter Test Bench Manufactures

Three Phase Stationary Meter Test Bench Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou GENY Electric Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)