Sign In | Join Free | My entremaqueros.com
China Guangzhou GENY Electric Co., Ltd logo
Guangzhou GENY Electric Co., Ltd
Professional in Energy Meter Testing
Verified Supplier

2 Years

Home > Stationary Power Source >

YCS-103/101 Series High-Precision Harmonic Power Equipment OEM / ODM Services

Guangzhou GENY Electric Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

YCS-103/101 Series High-Precision Harmonic Power Equipment OEM / ODM Services

Brand Name : GENY

Model Number : YCS-103

Certification : ISO, CE

Place of Origin : China

MOQ : 1

Price : negotiate rates

Payment Terms : T/T, L/C, D/P, T/T

Supply Ability : 5 sets / 1 months

Delivery Time : 6~8weeks

Packaging Details : Plywood cases

Test voltage output : 3×(24V – 288V) or customized

Power of the voltage output : 3×100VA/3×250VA/3×500VA/3×1000VA

Test current output : 3×(1mA – 100A)

Phase angle range : 0 -- 360°

Relative humidity : 35% -- 85%

Ambient temperature : -10°C -- +40°C

Voltage Supply : 3×220/380V±10% or customized 50/60Hz±2Hz

Contact Now

YCS-103/101 Series High-Precision Harmonic Power Equipment OEM/ODM Services

Description:

YCS—103

  • Constructed from aluminum alloy materials, this device boasts a combination of lightweight properties and robustness, effectively preventing corrosion while ensuring high accuracy and stability in output.
  • Equipped with an optional keyboard, facilitating manual operation as needed.
  • Capable of outputting from the 2nd to the 21st harmonic, with programmable amplitudes and degrees.
  • Easily operable via PC control software suite, streamlining operation processes.
  • Features an RS232 interface, enabling automatic operation and integration with external systems.
  • Incorporates protective measures against overload, short voltage circuits, and open current circuits, ensuring safety and reliability during operation.

YCS-101

  • High accuracy and high stability source output
  • With RS232 interface for automatic operation
  • With keyboard for manual operation (optional).
  • 2nd – 21st harmonic, output amplitude and degree can be programmed.
  • Aluminum alloy materials, light and strong, prevent corrosion.
  • With the protect function of overload, short voltage circuit and open current circuit.
  • PC control software suit, easy operation and support secondary software development

Technical Specifications:

ParameterYCS-103-250YCS-103-600YCS-103-1200YCS-103-2500
Voltage
Test Voltage Output (Phase-Neutral)3×(24V – 288V) or customized3×(24V – 288V) or customized3×(24V – 288V) or customized3×(24V – 288V) or customized
Power of the Voltage Output3×100VA3×250VA3×500VA3×1000VA
ResolutionBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of range
Setting AccuracyBetter than 0.05% at the final range valueBetter than 0.05% at the final range valueBetter than 0.05% at the final range valueBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)
Load Regulation from 0-max. Load< 0.01%< 0.01%< 0.01%< 0.01%
Distortion Factor< 0.3% for linear resistance load< 0.3% for linear resistance load< 0.3% for linear resistance load< 0.3% for linear resistance load
Harmonics (2nd – 21st)Free programmableFree programmableFree programmableFree programmable
Current
Test Current Output3×(1mA – 100A)3×(1mA – 100A)3×(1mA – 100A)3×(1mA – 100A)
Power of the Current Output3×150VA3×350VA3×750VA3×1500VA
ResolutionBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of range
Setting AccuracyBetter than 0.05% at the final range valueBetter than 0.05% at the final range valueBetter than 0.05% at the final range valueBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)
Load Regulation from 0-max. Load< 0.01%< 0.01%< 0.01%< 0.01%
Distortion Factor< 0.3% for linear resistance load< 0.3% for linear resistance load< 0.3% for linear resistance load< 0.3% for linear resistance load
Harmonics (2nd – 21st)Free programmableFree programmableFree programmableFree programmable
Phase Angle
Range0 -- 360°0 -- 360°0 -- 360°0 -- 360°
Resolution0.01°0.01°0.01°0.01°
Setting Accuracy0.1°0.1°0.1°0.1°
Frequency
Range45Hz – 65Hz45Hz – 65Hz45Hz – 65Hz45Hz – 65Hz
Resolution0.01Hz0.01Hz0.01Hz0.01Hz
Voltage Supply
Voltage Supply3×220/380V±10% or customized3×220/380V±10% or customized3×220/380V±10% or customized3×220/380V±10% or customized
Frequency50/60Hz±2Hz50/60Hz±2Hz50/60Hz±2Hz50/60Hz±2Hz
Operating Conditions
Ambient Temperature-10°C -- +40°C-10°C -- +40°C-10°C -- +40°C-10°C -- +40°C
Relative Humidity35-- 85%35% -- 85%35% -- 85%35% -- 85%

YCS-101-250YCS-101-600YCS-101-1200YCS-101-2500
Voltage Source
Test voltage output (Phase-Neutral)24V – 288V or customized
Power of the voltage output100VA250VA500VA1000VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load< 0.01%
Distortion factor< 0.3% for linear resistance load
Harmonics2nd – 21st free programmable
Current Source
Test current output1mA – 100A
Power of the current output150VA350VA750VA1500VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load< 0.01%
Distortion factor< 0.3% for linear resistance load
Harmonics2nd – 21st free programmable
Phase angle
Range0 -- 360°
Resolution0.01°
Setting accuracy0.1°
Frequency
Range45Hz – 65Hz
Resolution0.01Hz
Voltage Supply220V±10% or 50/60Hz±2Hz or customized
Ambient temperature-10°C -- +40°C
Relative humidity35% -- 90%

YCS-103/101 Series High-Precision Harmonic Power Equipment OEM / ODM Services


Product Tags:

High-Precision Harmonic Power Equipment

      

YCS-103/101 Harmonic Power Equipment

      

Harmonic Power Equipment

      
 YCS-103/101 Series High-Precision Harmonic Power Equipment OEM / ODM Services Manufactures

YCS-103/101 Series High-Precision Harmonic Power Equipment OEM / ODM Services Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou GENY Electric Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)